The knowledge of the operation of the fire fighting equipment must be known.

Fire fighting equipment is fire facilities and fire fighting equipment collectively, including fire facilities including fire automatic alarm system and automatic fire extinguishing system, fire hydrant system, anti smoke exhaust system and emergency broadcasting and emergency lighting, safety evacuation facilities, fire fighting equipment is refers to all kinds of fire extinguishers and fire extinguishing tools etc.. Today, China is to explain you must know knowledge of the operation of fire equipment.

(a) what is the purpose and the specification of the guide rope? How safe to use?

Rope guide is mainly used for firefighters to enter the smoke or low visibility and terrain, complex building structure dangerous area, hold the attack, egress direction or keep in touch with the external rope, including team with guide lines and personal guide rope. The withdrawal of the scene in the direction of team with the length of the rope guide for 60 meters (can be determined according to needs, appropriate to extend) rope every 3 meters have a group of sagging of the rope marks that node short rope head (50 mm long) that entered the scene direction, without a long rope head (100 mm long). The length of the individual with the guide rope is 6 meters. Before use must be firmly connected to each connection point, bearing in mind that the direction of the direction of the withdrawal of the rope with the head signs (according to the needs of other protective equipment and supporting the use).

(two) what is the purpose and method of use the device?

Device for fire fighting personnel or other persons from the height of slow downhill life. Can be recycled, continuous rescue. By hook or ring, speed controller, life-saving belt and safety rope etc.. When in use, one end of the safety rope is sheathed in the armpit of the rescued person, and the other end is fixed on the object near the window or the balcony. Its shape was round drum shape, weight 2.7 kg, length of up to 30 meters.

(three) how to use insulated scissors, insulated gloves and insulated boots?

Insulation for firefighters to extinguish the fire in the cut when the cut wire, cut off the power supply with the use of fire, a large and small two. Insulated gloves have two types of rubber products and latex products, sub 12KV and 5KV two, mainly for the operation of high voltage power equipment. 12 kV insulated gloves when using voltage 1kV above for auxiliary and safe appliance, 1kV and below for basic and safe appliance. 5kV insulation gloves is forbidden to be used when using voltage 1kV above, below 1kV for auxiliary safety equipment, 0.25KV for basic and safe appliance. Insulation boots is used with to keep safe appliance auxiliary insulation, basic and safe appliance is door step voltage.

Back